Architectural Wood Sidelites & Borrowed Lites


  • FlameTech® 20 & 45 minute fire-rated Sidelights & Borrowed Lites
  • Linear and compound radius multiple lite wall installations
  • AWI Premium Grade fastener-less frames
  • Lock miter frames
  • Custom matched veneer frames, jambs, casing and trim
  • Color & grain matched or blueprint-matched to panels and doors
  • Shipped pre-assembled or knocked-down
Borrowed Lite Cutaway

FlameTech® 20 Minute Wood Sidelite

Fire Rating
20 Minute, Negative Pressure UL, ITS (Warnock Hersey)
Construction Material
Solid Wood
any species which meets the Minimum Density Requirements
Maximum Size
4/6x 9/0 assembly
No individual visible glass zie may be greater than 1296 sq.in.
Minimum
Jamb Width
3-3/4"
in wood/steel stud or masonry
Intumescent
Material
None used
Gasketing
Material
None used
Stop Application: Field or shop applied with 4d finish nails.
Sidelight and clips must be installed in accordance with NFPA #80 and #105 Latest Edition.

Borrowed Lite Cutaway

FlameTech® 45 Minute Wood Sidelight

Fire Rating
45 Minute, Positive Pressure UL, ITS (Warnock Hersey)
Construction Material
Solid Wood
any species which meets the Minimum Density Requirements
Maximum Size
5/6 x 9/0 assembly
No individual visible glass zie may be greater than 2810 sq.in.
Minimum
Jamb Width
4-15/16"
in wood/steel stud or masonry
Intumescent
Material
Pemko FG1000 (glass face) & Pemko FGS4000 (stop face)
Glazing
Approved fire-rated glass must be 1.4" less than opening, installed with FireClips™ and sealed with intumescent.
Min. Hinge Size: Per NFPA #80 Latest Edition Screw Requirements: At least one used to secure each hinge and latch
strike to stud must be 2-1/2" min. Frame must be installed in accordance with NFPA #80 and #105 Latest Edition.

Borrowed Lite Cutaway

FlameTech® 20 Minute Wood Borrowed Lite

Fire Rating
20 Minute, Negative Pressure UL, ITS (Warnock Hersey)
Construction Material
Solid Wood
any species which meets the Minimum Density Requirements
Maximum Size
7/0 x 8/8 assembly
No individual visible glass zie may be greater than 1296 sq.in.
Minimum
Jamb Width
3-3/4"
in wood/steel stud or masonry
Intumescent
Material
None used
Gasketing
Material
None used
Stop Application: Field or shop applied with 4d finish nails.
Sidelight and clips must be installed in accordance with NFPA #80 and #105 Latest Edition.

Borrowed Lite Cutaway

FlameTech® 45 Minute Wood Borrowed Lite

Fire Rating
45 Minute, Positive Pressure UL, ITS (Warnock Hersey)
Construction Material
Solid Wood
any species which meets the Minimum Density Requirements
Maximum Size
5/6 x 9/0 assembly
No individual visible glass zie may be greater than 2810 sq.in.
Minimum
Jamb Width
4-15/16"
in wood/steel stud or masonry
Intumescent
Material
Pemko FG1000 (glass face) & Pemko FGS4000 (stop face)
Glazing
Approved fire-rated glass must be 1.4" less than opening, installed with FireClips™ and sealed with intumescent.
Min. Hinge Size: Per NFPA #80 Latest Edition Screw Requirements: At least one used to secure each hinge and latch
strike to stud must be 2-1/2" min. Frame must be installed in accordance with NFPA #80 and #105 Latest Edition.