- FlameTech® 20 & 45 minute fire-rated wood frames and lites
- FlameTech® 60 & 90 minute fire-rated veneer frames and lites
- Linear and compound radius multiple lite wall installations
- AWI Premium Grade fastener-less frames
- Split jamb frames
- Lock miter frames
- Custom matched veneer frames, jambs, casing and trim
- Color & grain matched or blueprint-matched to panels and doors
- Shipped pre-assembled or knocked-down
- Rear-fastened, T-profile door stops
FlameTech® 20 Minute Wood Door Frame
Fire Rating
20 Minute, Positive or Negative Pressure UL, ITS (Warnock Hersey)
Construction Material
Solid Wood
any species which meets the Minimum Density Requirements
any species which meets the Minimum Density Requirements
Maximum Size
8/0 x 9/0 assembly
Minimum Jamb Width
3-3/4"
in wood/steel stud or masonry
in wood/steel stud or masonry
Intumescent Material
Negative Pressure- None used
Positive Pressure- Pemko HSS2000
Positive Pressure- Pemko HSS2000
Gasketing Material
Negative Pressure - Any rated gaskets
Positive Pressure - Pemko S88
Positive Pressure - Pemko S88
Min. Hinge Size: Per NFPA #80 Latest Edition Screw Requirements: At least one used to secure each hinge and latch strike to stud must be 2-1/2" min. Frame must be installed in accordance with NFPA #80 and #105 Latest Edition.
FlameTech® 45 Minute Wood Door Frame
Fire Rating
45 Minute, Positive Pressure UL, ITS (Warnock Hersey)
Construction Material
Solid Wood
any species which meets the Minimum Density Requirements
any species which meets the Minimum Density Requirements
Maximum Size
6/0 x 9/0 assembly
Minimum
Jamb Width
Jamb Width
4-15/16"
in wood/steel stud or masonry
in wood/steel stud or masonry
Intumescent
Material
Material
Pemko HSS2000
Gasketing
Material
Material
Pemko S88
Min. Hinge Size: Per NFPA #80 Latest Edition Screw Requirements: At least one used to secure each hinge and latch
strike to stud must be 2-1/2" min. Frame must be installed in accordance with NFPA #80 and #105 Latest Edition.
strike to stud must be 2-1/2" min. Frame must be installed in accordance with NFPA #80 and #105 Latest Edition.
FlameTech® 60 Minute Wood Door Frame
Fire Rating
60 Minute, Positive Pressure ITS (Warnock Hersey)
Construction Material
Wood Veneer
Maximum Size
7/0 x 8/0 assembly
Minimum
Jamb Width
Jamb Width
4-3/4"
in wood/steel stud or masonry
in wood/steel stud or masonry
Intumescent
Material
Material
Embedded & Concealed
Gasketing
Material
Material
N/A
Min. Hinge Size: Per NFPA #80 Latest Edition Screw Requirements: At least one used to secure each hinge and latch
strike to stud must be 2-1/2" min. Frame must be installed in accordance with NFPA #80 and #105 Latest Edition.
strike to stud must be 2-1/2" min. Frame must be installed in accordance with NFPA #80 and #105 Latest Edition.
FlameTech® 90 Minute Wood Door Frame
Fire Rating
90 Minute, Positive Pressure ITS (Warnock Hersey)
Construction Material
Wood Veneer
Maximum Size
7/0 x 8/0 assembly
Minimum
Jamb Width
Jamb Width
5"
in wood/steel stud or masonry
in wood/steel stud or masonry
Intumescent
Material
Material
Embedded & Concealed
Gasketing
Material
Material
N/A
Min. Hinge Size: Per NFPA #80 Latest Edition Screw Requirements: At least one used to secure each hinge and latch
strike to stud must be 2-1/2" min. Frame must be installed in accordance with NFPA #80 and #105 Latest Edition.
strike to stud must be 2-1/2" min. Frame must be installed in accordance with NFPA #80 and #105 Latest Edition.